The latency tracking is done with ranges of bucket arrays.
The bucket for any given I/O is determined solely by TSC
deltas - any translation to microseconds is only done after
the test is finished and statistics are printed.
Each range has a number of buckets determined by a
NUM_BUCKETS_PER_RANGE value which is currently set to 128.
The buckets in ranges 0 and 1 each map to one specific TSC
delta. The buckets in subsequent ranges each map to twice
as many TSC deltas as buckets in the previous range:
Range 0: 1 TSC each - 128 buckets cover deltas 0 to 127
Range 1: 1 TSC each - 128 buckets cover deltas 128 to 255
Range 2: 2 TSC each - 128 buckets cover deltas 256 to 511
Range 3: 4 TSC each - 128 buckets cover deltas 512 to 1023
Range 4: 8 TSC each - 128 buckets cover deltas 1024 to 2047
Range 5: 16 TSC each - 128 buckets cover deltas 2048 to 4095
etc.
While here, change some variable names and usage
messages to differentiate between the existing latency
tracking via vendor-specific NVMe log pages on Intel
NVMe SSDs, and the newly added latency tracking done
in software.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I299f1c1f6dbfa7ea0e73085f7a685e71fc687a2b