[psm] Fix choosing wrong mode for synaptic device + trackpoint

With guest trackpoint present trackpoint probing switched synaptics
device to absolute mode with different protocol instead of keeping it
in relative mode.

PR:		213757
Submitted by:	Vladimir Kondratyev <wulf@cicgroup.ru>
MFC after:	1 week
This commit is contained in:
Oleksandr Tymoshenko 2016-11-02 01:27:20 +00:00
parent eecaab5275
commit dcc414b888
Notes: svn2git 2020-12-20 02:59:44 +00:00
svn path=/head/; revision=308189

View File

@ -1062,27 +1062,15 @@ doopen(struct psm_softc *sc, int command_byte)
*/
if (sc->hw.model == MOUSE_MODEL_GENERIC) {
if (tap_enabled > 0) {
/*
* Enable tap & drag gestures. We use a Mode Byte
* and clear the DisGest bit (see §2.5 of Synaptics
* TouchPad Interfacing Guide).
*/
VLOG(2, (LOG_DEBUG,
"psm%d: enable tap and drag gestures\n",
sc->unit));
mouse_ext_command(sc->kbdc, 0x00);
set_mouse_sampling_rate(sc->kbdc, 20);
synaptics_set_mode(sc, synaptics_preferred_mode(sc));
} else if (tap_enabled == 0) {
/*
* Disable tap & drag gestures. We use a Mode Byte
* and set the DisGest bit (see §2.5 of Synaptics
* TouchPad Interfacing Guide).
*/
VLOG(2, (LOG_DEBUG,
"psm%d: disable tap and drag gestures\n",
sc->unit));
mouse_ext_command(sc->kbdc, 0x04);
set_mouse_sampling_rate(sc->kbdc, 20);
synaptics_set_mode(sc, synaptics_preferred_mode(sc));
}
}
@ -5364,6 +5352,24 @@ static int
synaptics_preferred_mode(struct psm_softc *sc) {
int mode_byte;
/* Check if we are in relative mode */
if (sc->hw.model != MOUSE_MODEL_SYNAPTICS) {
if (tap_enabled == 0)
/*
* Disable tap & drag gestures. We use a Mode Byte
* and set the DisGest bit (see §2.5 of Synaptics
* TouchPad Interfacing Guide).
*/
return (0x04);
else
/*
* Enable tap & drag gestures. We use a Mode Byte
* and clear the DisGest bit (see §2.5 of Synaptics
* TouchPad Interfacing Guide).
*/
return (0x00);
}
mode_byte = 0xc4;
/* request wmode where available */
@ -5382,10 +5388,10 @@ synaptics_set_mode(struct psm_softc *sc, int mode_byte) {
/*
* Enable advanced gestures mode if supported and we are not entering
* passthrough mode.
* passthrough or relative mode.
*/
if ((sc->synhw.capAdvancedGestures || sc->synhw.capReportsV) &&
!(mode_byte & (1 << 5))) {
sc->hw.model == MOUSE_MODEL_SYNAPTICS && !(mode_byte & (1 << 5))) {
mouse_ext_command(sc->kbdc, 3);
set_mouse_sampling_rate(sc->kbdc, 0xc8);
}
@ -5698,6 +5704,9 @@ enable_synaptics(struct psm_softc *sc, enum probearg arg)
if (!synaptics_support)
return (FALSE);
/* Set mouse type just now for synaptics_set_mode() */
sc->hw.model = MOUSE_MODEL_SYNAPTICS;
synaptics_set_mode(sc, synaptics_preferred_mode(sc));
if (trackpoint_support && synhw.capPassthrough) {