The first could occur because the original code would continue to reset
the SCSIID register while waiting for a selection. This could potentially
conflict with a reconnect since a successfull reconnect will also set the
SCSIID register. The fix is to use a separate wait loop after starting
a selection (as was done a few revisions ago).
The second probably never happens, but it was possible for a target to
reconnect while there was a pending SCB on the waiting list and not get
noticed. The fix was to remove a supurflous check of the scb waiting
list.
by me). This probably loses for multibyte characters, but I have no
way of telling. I'll let ache decide whether to add this support to
startup_setlocale. Note that for this to make any sense at all, the
symlinks in /usr/share/locale must go. (For the moment, this doesn't
make any difference since there are no locales supplied.)
Obtained from: Arthur David Olson <ado@elsie.nci.nih.gov>
LINK_SPEC. This solves a problem with the f77 frontend where
aproviding the -r8 option (use REAL*8) caused `cc' to ``forget'' to
pass the entry point to the linker.
Closes PR #gnu/644: f77 -r8
Reviewed by: watanabe@komadori.earth.s.kobe-u.ac.jp (Takeshi WATANABE)
comparisions have been made as string comparisions, even in cases
where both operands clearly qualified as integers.
The fix is to make the parser properly analyzing whether an operand is
a valid integer or not.
is 1996 EC harmonization. Also, the following timezones have been renamed:
Asia/Frunze -> Asia/Bishkek
Pacific/Cocos -> Indian/Cocos
Pacific/Belau -> Pacific/Palau
America/Navajo -> America/Shiprock
and one new timezone has been added:
Australia/Canberra
Basically all termios+termcap pgms needs it.
It set ospeed variable using nearest-matched stty speeds,
which helps termcap pgms works with non-fixed termios speeds
and not duplicate ospeed switch into every pgm.
Also it isn't standard function, its source code is too big to include it
in whole to every termcap+termios pgm.
I do some digging out on this subject and found that remote
rlogind may reduce big speeds to 38400 by itself and (as more often
rlogind variant) speed setting ioctl fails, so speed left on 9600.
In all cases it doesn't do any real harm.
Detect in nfsrv_readdirplus when a filesystem soes not support VFS_VGET and
return NFSERR_NOTSUPP so that the client will use ordinary readdir instead.
I get on this topic will go straight to /dev/null. This is absolutely the
last word on this topic you'll see from me. Too much time has already been
wasted.
flag. The getopt handling in here is actually pretty bogus (not Phil's
fault - it's original sin) but the general approach is working so I'm not
going to break it. Some small tweaks of my own to add error checking to what
was originally submitted. Strange how nobody noticed that the flag was
documented but completely missing from the code before! [jkh].
Submitted by: Phil Taylor <phil@zipmail.co.uk>