One of the fun issues with scanning has been how the existing ANI values were programmed into the hardware when channels were changed. If you're on a really crappy channel and ANI has made you deaf then when you scan you continue to be deaf on all channels. This code passes in a flag to startpcureceive which in AR5416 and later is also used to enable ANI. This allows it to know if it's a normal operation or a scan operation. This fixes my situation at home where a temporary spot of a device going deaf due to interference starts scanning and .. can't hear anything until I restart. Now, this isn't the full fix - ideally: (a) all the ANI config and per-channel information would be migrated to the shared HAL stuff and enabled for all of the NICs; (b) when a station reassociates and some other error conditions (like missed beacons, NF calibration failures, etc) a knob to reset ANI parameters would likely help recovery. But hey, I'm committing bits of code again! woo! Tested: * AR9344 (2G), STA operation |
||
---|---|---|
.. | ||