I'm able to suspend/resume my laptop without this change, but then I need
to wait for the watchdog to reset the card.
With this change, it is ready immediately.
Glanced at by: glebius
IFF_DRV_RUNNING, as well as the move from ifnet.if_flags to
ifnet.if_drv_flags. Device drivers are now responsible for
synchronizing access to these flags, as they are in if_drv_flags. This
helps prevent races between the network stack and device driver in
maintaining the interface flags field.
Many __FreeBSD__ and __FreeBSD_version checks maintained and continued;
some less so.
Reviewed by: pjd, bz
MFC after: 7 days
over iteration of their multicast address lists when synchronizing the
hardware address filter with the network stack-maintained list.
Problem reported by: Ed Maste (emaste at phaedrus dot sandvine dot ca>
MFC after: 1 week
a problem with one particular switch module. Create a kernel option
BGE_FAKE_AUTONEG that restores the 5.4 behavior, which should make the DNLK
switch module work. IBM/Intel blades with Intel or AD switch modules should
work without patching or kernel options with this commit.
Hardware for testing provided by several folks, including
Danny Braniss <danny@cs.huji.ac.il>, Achim Patzner <ap@bnc.net>,
and OffMyServer.
Approved by: re
struct ifnet or the layer 2 common structure it was embedded in have
been replaced with a struct ifnet pointer to be filled by a call to the
new function, if_alloc(). The layer 2 common structure is also allocated
via if_alloc() based on the interface type. It is hung off the new
struct ifnet member, if_l2com.
This change removes the size of these structures from the kernel ABI and
will allow us to better manage them as interfaces come and go.
Other changes of note:
- Struct arpcom is no longer referenced in normal interface code.
Instead the Ethernet address is accessed via the IFP2ENADDR() macro.
To enforce this ac_enaddr has been renamed to _ac_enaddr.
- The second argument to ether_ifattach is now always the mac address
from driver private storage rather than sometimes being ac_enaddr.
Reviewed by: sobomax, sam
entered the interface start function, no packets were actually dequeued.
Therefore, keep a count of how many packets we really added onto the tx
chain, and initiate a transmit only if the count is non-zero.
frames. BGE hardware with the rx alignment bug will still be handled by the
calls to m_adj() that already exist. m_adj() is probably better suited for
this task anyways. Just as with if_em, this saves a malloc + several locks
per packet and prevents unneeded data copying within busdma.
I have from Broadcom does not give much information on these devices,
so the Broadcom Linux driver was used for clues to what these chips
support. It turns out they are similar to the 5705 with the 5751
being the PCI-Express version and needing special work-arounds and
settings.
copper NICs, a link change event is posted whenever MII autopolling is
toggled off and on, which happens whenever someone calls
bge_miibus_readreg() or bge_miibus_writereg() to access the PHY
registers. This means anytime someone called the SIOCGIFMEDIA ioctl
on a bge interface, the link would reset. Even a simple "ifconfig bge0"
would do it, though other apps like dhclient or the PPPoE daemon could
trigger it as well. An obvious symptom of this problem is lots of
"bgeX: gigabit link up" messages appearing on the console for no
apparent reason.
Through experimentation, I determined that when a real link change
event occurs, the BGE_MIMODE_AUTOPOLL in the BGE_MI_MODE register
is always set, so now if we have a copper NIC and an link change
event occurs and the BGE_MIMODE_AUTOPOLL bit is clear, we ignore
the event.
Note that this does not apply to the original BCM5700 chip since we
use a different method for sensing link changes with that chip (the
status block method was broken), nor to fiber optic NICs since they
don't use the GMII PHY access registers.
(in particular, bge(4) hasn't supported rxcsum since if_bge.c#1.5)
Clean up some aspects of capabilities usage, i.e. stop using
if_hwassist to see whether we are doing offload now because if_hwassist
is for TCP/IP layer and it is subordinate to if_capenable.
Thanks to: Aled Morris for donating a nice bge(4) NIC to me
Reviewed by: -net, -hackers (silence)
mode. The 5704 apparently has some s00p3r s33kr1t registers for setting
the advertisement of pause frame ability (i.e flow control) when in
autoneg mode. If we don't set these registers correctly, we may not
be able to negotiate a proper link with some switches. (Symptom is that
the NIC reports the link as up (PCS synched) but no traffic can be
exchanged.)
PR: kern/67598
multicast hash are written. There are still two distinct algorithms used,
and there actually isn't any reason each driver should have its own copy
of this function as they could all share one copy of it (if it grew an
additional argument).
if_xname, if_dname, and if_dunit. if_xname is the name of the interface
and if_dname/unit are the driver name and instance.
This change paves the way for interface renaming and enhanced pseudo
device creation and configuration symantics.
Approved By: re (in principle)
Reviewed By: njl, imp
Tested On: i386, amd64, sparc64
Obtained From: NetBSD (if_xname)
These are 10/100 only NICs found on the IBM Thinkpad R40E and
G40. These seem to be based on the BCM5705 MAC but with a PHY
that doesn't support 1000Mbps modes.
Submitted by: Igor Sviridov <sia@nest.org>
to configure this correctly yields many watchdog timeouts even on lightly
loaded machines. This is a common complaint from users with Dell 1750
servers with built-in dual 5704 NICs.
BGE_MACSTAT_MI_COMPLETE bit in the MAC status register as a link
change indicator. We turn this bit on now because some of the newer
chips need it, but it usually just means that reading/writing
an MII/GMII register has completed, not that a link change has
occured.