Add some mention of the functions used by protocol implementations,
upcalls, and other general routines.
Not all functionality is documented; in particular:
o the *at() variants, which are useful only for implementing the
corresponding syscalls.
o soconnect2(), also only used to implement a syscall (socketpair()).
o sockargs(), which is essentually unused and only tangentially
socket-related.
o selsocket(), which is commented as being present solely for use by
netncp and netsmb.
o getsockaddr(), which is just a convenience shortcut for copyin().
Reviewed by: jhb (previous version)
Approved by: hrs (mentor)
through a voltage divisor (R163 and R164 on page 4 of BBB schematic).
Add a note about this on ti_adc(4) man page. The ti_adc(4) man page will
first appear on 10.1-RELEASE.
MFC after: 1 week
Suggested by: Sulev-Madis Silber (ketas)
Manual page reviewed by: brueffer (D127)
Reorganize the previous contexts of the file as it is in Linux. The
eventual goal is to install the header files and share them between
the kernel and bhyve.
MFC after: 1 week
This _was_ right, a last minute suggestion and not enough testing makes
Adrian a bad boy.
Tested:
* igb(4) with RSS patches, by hand verifying each igb(4) taskqueue
tid from procstat -ka using cpuset -g -t <tid>.
If the user specifies in /boot/loader.conf:
loader_brand="mycustom-brand"
Then "mycustom-brand" will be executed instead of "fbsd-logo".
Submitted by: alfred
Obtained from: FreeNAS
and the actual PWM frequency.
Enforce the maximum value for the period sysctl.
The frequency systcl now allows the direct setting of the PWM frequency (it
will try to find the better clkdiv and period for a given frequency, i.e.
the ones that will give the better PWM resolution).
This allows the use lower frequencies on the PWM. Without changing the
clock prescaler the minimum PWM frequency was 1.52kHz.
PWM frequencies checked with an osciloscope.
PWM output tested with some R/C servos at 50Hz.
the system.
Together with lm75(4) this module allows easy temperature monitoring over
SNMP, specially for embedded systems.
Manual page reviewed by: brueffer (D128)
to 16. This is arbitrary and is used to ensure that a vcpu goes back into
the vm_run() loop to process interrupts or rendezvous events in a timely
fashion.
Found with: Coverity Scan
CID: 1216436
it implicitly in vmm.ko.
Add ioctl VM_GET_CPUS to get the current set of 'active' and 'suspended' cpus
and display them via /usr/sbin/bhyvectl using the "--get-active-cpus" and
"--get-suspended-cpus" options.
This is in preparation for being able to reset virtual machine state without
having to destroy and recreate it.
Put the superblock in the correct possition for UFS2... There is a bug
in FFS that if we don't put it here (for UFS2), it will forcefully
relocate the superblock, and I believe cause data loss..
I have a fix for that, but w/ how many releases are broken, we won't be
able to switch to the better _FLOPPY (block 0) for this for a while..
flag has been added instead of FUTEX_WAIT to replace the FUTEX_WAIT
logic which needs to do gettimeofday() calls before the futex syscall
to convert the absolute timeout to a relative timeout.
Before this the CLOCK_MONOTONIC used by the FUTEX_WAIT_BITSET op.
When the FUTEX_CLOCK_REALTIME is specified the timeout is an absolute
time, not a relative time. Rework futex_wait to handle this.
On the side fix the futex leak in error case and remove useless
parentheses.
Properly calculate the timeout for the CLOCK_MONOTONIC case.
MFC after: 3 days
At attach, print the SCL and SDA pin numbers.
Remove a stray blank line.
Remove the GPIOBUS locking from gpioiic_reset(), it is already called with
this lock held. This fixes a crash when you try to scan the iicbus with
i2c(8).
This is not really a good test as the behaviour for /c is unspecified.
For the record, ksh93 returns:
$ printf "abc\n\cdef"
abc
ef$
Discussed with: Garret D'Amore (Illumos)
get_scatter_segment() in get_fl_payload() fails. While here,
fix the code to adjust fl_bufs_used when a failure occurs for
any other scatter segment.
MFC after: 3 days
displays after a pause, use the difference in runtime divided by the
length of the pause as the percentage of CPU used instead of the value
calculated by the kernel. In addition, when determing if a process or
thread is idle or not, treat any process or thread that has used any
runtime or performed any context switches during the interval as busy.
Note that the percent CPU is calculated as a double and stored in an
array to avoid recalculating the value multiple times in the comparison
method used to sort processes in the CPU display.
Tested by: Jamie Landeg-Jones <jamie@dyslexicfish.net>
Reviewed by: emaste (earlier version)
MFC after: 1 week
prevents surprising effects post-installation on serial-only x86 systems
(e.g. bhyve) where the kernel messages will appear, rc scripts will run,
and then there will be no login prompt and you will be locked out of the
system.
Thanks to Devin Teske and Peter Grehan for ideas and testing. With this
patch, it may also be possible to unify all or most of the machine-specific
ttys files.