- Document how an event looks like that is received by devd(8) from acpi_ibm(4)
- Document the event codes as they occur on a T41p
- Add a note about sysctl.conf and an Xref to it
- Add an example section providing an example script and an entry for
devd.conf. This is an adapted version of the one in acpi_fujitsu(4).
- s/Fn-F4/Fn+F4/ for consistency sake
- Add a button description where refering to a T41p, remove it otherwise,
since it might vary from model to model
- Bump .Dd
Thanks for improvements to: brueffer, ru
Approved by: brueffer
fast, lightweight, and generally good way for users to keep their
ports trees up to date.
This is version 0.9.4 from the ports tree (sysutils/portsnap) with
the following changes:
1. The experimental pipelined http code is enabled. No seatbelts
in -CURRENT. (^_^)
2. The working directory has moved from /usr/local/portsnap to
/var/db/portsnap (as discussed on -arch two days ago).
3. Portsnap now fetches a list of mirrors (distributed as DNS SRV
records) and selects one randomly. This should help to avoid the
uneven loading which plagues the cvsup mirror network.
4. The license is now 2-clause BSD instead of 3-clause BSD.
5. Various incidental changes to make portsnap fit into the base
system's build mechanics.
X-MFC-After: 6.0-RELEASE
X-MFC-Before: 5.5-RELEASE
X-MFC-To: RELENG_6, RELENG_5, ports
discussed on: -arch and several other places
"yes please" from: simon, remko, flz, Diane Bruce
thinks this is a great idea: bsdimp
Hopes he didn't forget any files: cperciva
- Add a note about the organisation of the sections.
- Expand shell globs (they worked in a previous version of the delete-old
target, but not in this one).
- Use the correct way of checking for a native environment. [1]
- Add some more obsolete files.
- Fix some bad english. [1]
Suggested by: ru [1]
Approved by: mentor (joerg)
- removes obsolete files/dirs or libraries.
- works in interactive (default) and batch mode
- respects DISTDIR
- documented in UPDATING and build(7)
The head of the file ObsoleteFiles.inc contains instructions how to add
obsolete files/dirs/libs to the list. Obviously one should add obsolete
files to this list, when he removes a file/dir/lib from the basesystem.
Additionally add check-old target:
- allows re@ to check if a file on the obsolete list resurfaces
Design goals:
- allows full control by the user (default interactive mode)
- possibility of scripted removal of obsolete files (batch mode)
- opt-in removal of files (explicit list of files)
- seperate removal of libs (2 delete targets)
Important design decissions:
- structured list of files to remove instead of a plain text file:
* allows to remove additional files if a NO_foo knob is specified
without the need to change the targets (no NO_foo knob is respected
yet)
- not using mtree like NetBSD does:
* mtree doesn't has an interactive mode
Discussed on: arch (long ago), current (this year)
Additional input from: re (hrs)
Approved by: mentor (joerg)
and return a printable representation.
This fixes recognition of the PC Engines WRAP and improves the
recognition of the Soekris boards (Bios version can now be
seen in the dmesg output for instance).
Also, add watchdog support for PCM-582x platforms.
Submitted by: Adrian Steinmann <ast@marabu.ch>
Slightly changed by: phk
PR: 81360