Otherwise sysbeep() makes an annoying clicking sound on some systems.
'kbdcontrol -b off' just sets the duration and pitch to zero, it doesn't
set the QUIET_BELL flag.
Tested by: SorAlx <soralx@cydem.zp.ua>
PR: misc/41772
MFC after: 1 week
when WARNS was increased recently, but __printf0like() has been
temporarily disabled for 8 months.
Fixed related style bugs (disordered declaraction and silly type for
maxpayload -- assume 16-bit ints like the rest of ping.c).
fifo_open() waiting for another reader or writer if one arrived and
departed while we were waiting (or a little earlier).
Rev.1.79 broke blocking opens of fifos by making them time out after 1
second. This was bad for at least apsfilter.
Tested by: "Simon 'corecode' Schubert" <corecode@corecode.ath.cx>,
Alexander Leidinger <Alexander@leidinger.net>,
phk
MFC after: 4 weeks
doesn't do it. This fixes all known causes of "Context switches not
allowed in the debugger" in mi_switch(). The main cause was trap_fatal()
calling kdb_trap() with interrupts enabled. Switching to ithreads for
interrupt handling then made fatal traps more fatal and harder to debug.
The problem was limited in -current because most interrupt handlers are
blocked by Giant, but it occurred almost deterministically for me because
my clock interrupt handlers are non-fast and not blocked by Giant.
- Clear PCIM_CMD_MWRICEN:
some chips seem to have problem with write invalidate.
clearing this bit fixes SBP timeout problem.
Tested by: Michael Reifenberger <Michael.Reifenberger@Plaut.de>
- Set PCIM_CMD_SERRESPEN and PCIM_CMD_PERRESPEN
- Moderate value for latency timer.
the child process, before executing the command. This is very useful
when you do stuff like ``find ... | xargs interactive_application''.
Without -o, the application would inherit the pipe as its stdin, and
you thus lose any control over it.
This flag has been carefully chosen to not conflit with other options
of other xargs utilities like GNU xargs.
Reviewed by: jmallett
which are no longer required now that we have UFS2 with extended
attribute transactions.
Obtained from: TrustedBSD Project
Sponsored by: DARPA, Network Associates Laboratories
Change 27224 by imp@imp_hammer on 2003/03/22 00:16:22
Put what I think are the correct TX RATE translation tables
in place for LUCENT firmware. This is based on the 4.x driver.
Maybe it should be table driven?
ifconfig wi0 media DS/11Mbps still fails, but it fails before
we even get to the txrate stuff, so other things are wrong.
Change 27225 by imp@imp_hammer on 2003/03/22 00:45:11
Default ic_fixed_rate to -1. This is the same thing as autoselect.
There really should be a #define for this...
- Use it in atacontrol(8) when listing ATA devices instead of
stopping at the first ENXIO received.
This makes atacontrol list work on my sparc64 where the two ATA
channels I have are numbered 2 and 3.
Reviewed by: sos