During acpi_cmbat_attach() the acpi_cmbat_init_battery() notification
handler is registered. It has been observed this notification handler
can be called instantly, before the attach routine has returned. In
the notification handler there is a call to device_is_attached() which
returns false. Because the softc is set we know an attach is in
progress and the fix is simply to wait and try again in this case.
Reviewed by: avg @