actually 16 I/O lines but the other ones are used for system devices and
interrupts.
The IXP4XX platform can set interrupts on these pins for
high/low/rising/falling/transitional but this is not implemented yet.
The Cambria has the same interface but as all the pins are assigned to system
functions the gpio header is toggled via a PLD on the i2c bus and is not
supported by this commit.
function from the timer code to util, rename it appropriately and
also fix a bug in sctp_get_prev_mtu(), where calling it with a
value existing in the MTU table did not return a smaller one.
MFC after: 3 days.
because there's inter-entry garbage, just scan forward
to find the next one. This allows us to handle a lot
of Zip archives that have been modified in-place.
Thanks to: Gleb Kurtsou for sending me a sample archive
controllers. sk(4) never reprogrammed station address for Yukon
controllers so overriding station address with ifconfig(8) was not
possible.
Fix the bug by reprogramming all registers that control station
address, flow-control and virtual station address. Virtual station
address has no use at this moment since driver does not make use of
fail over feature.
Tested by: "Mikhail T." <mi+thun <> aldan.algebra.com>
MFC after: 1 week
the IEEE80211_C_RATECTL flag set, default to NONE for all drivers. Only if
a driver calls ieee80211_ratectl_init() check if the NONE algo is still
selected and try to use AMRR in that case. Drivers are still free to use
any other algo by calling ieee80211_ratectl_set() prior to the
ieee80211_ratectl_init() call.
After this change it is now safe to assume that a ratectl algo is always
available and selected, which renders the IEEE80211_C_RATECTL flag pretty
much useless. Therefore revert r211314 and 211546.
Reviewed by: rpaulo
MFC after: 2 weeks
The crash was caused by a command line such as this one:
# foldl -b1
PR: bin/151592
Reported by: Marcus Reid <marcus@blazingdot.com>
Tested by: Marcus Reid <marcus@blazingdot.com>
MFC after: 3 days
- For the parallel stable/7 and stable/8 branches mention both releases that
first supported a particular sparc64 machine and update the sparc64 hardware
list regarding machines that will be supported beginning with 7.4-RELEASE.
what we have. Without the check the kernel could accessing memory that
does not belong to the request struct.
Note that we do not test if the struct equals in size at this time, which
may faciliate forward compatibility with newer binaries.
Reviewed by: pjd at MeetBSD CA '2010
MFC after: 1 week
based devices (QUALCOMMINC 0x2000). He made it use SCSI eject instead of
ZTE STOR eject. This prevented my ZTE MF626 dongle from switching.
- Apply both eject methods for ZTE STOR based devices. Works on my as
well as mav's device.
- Remove the duplicate.
- Sort the usbdevs entries for Qualcomm so this won't happen again.
- Add bootverbose message displaying the fact that we are ejecting (and
how).
Reviewed by: mav
MFC after: 2 weeks
only for !usevget case. If VFS_VGET is working, the vnode shared lock
is obtained recursively and vput() shall be done, not vunref().
Submitted by: rmacklem
Tested by: Josh Carroll <josh.carroll gmail com>
MFC after: 3 days
copied as a template for _SRS, a string pointer for descriptor name is also
copied and it becomes stale as soon as it gets de-allocated[2]. Now _CRS is
used as a template for _SRS as ACPI specification suggests if it is usable.
The template from _PRS is still utilized but only when _CRS is not available
or broken. To avoid use-after-free the problem in this case, however, only
mandatory fields are copied, optional data is removed, and structure length
is adjusted accordingly.
Reported by: hps[1]
Analyzed by: avg[2]
Tested by: hps
useful counters like rl_missed_pkts is 16 bits quantity which is
too small to hold meaningful information happened in a second. This
means driver should frequently read these counters in order not to
lose accuracy and that approach is too inefficient in driver's
view. Moreover it seems there is no way to trigger an interrupt to
detect counter near-full or wraparound event as well as lacking
clearing the MAC counters. Another limitation of reading the
counters from RealTek controllers is lack of interrupt firing at
the end of DMA cycle of MAC counter read request such that driver
have to poll the end of the DMA which is a time consuming process
as well as inefficient. The more severe issue of the MAC counter
read request is it takes too long to complete the DMA. All these
limitation made maintaining MAC counters in driver impractical. For
now, just provide simple sysctl interface to trigger reading the
MAC counters. These counters could be used to track down driver
issues. Users can read MAC counters maintained in controller with
the following command.
#sysctl dev.re.0.stats=1
While I'm here add check for validity of dma map and allocated
memory before unloading/freeing them.
Tested by: rmacklem
information through devd. My E220 now produces the notification (1 line):
+u3g0 at bus=1 hubaddr=1 port=0 devaddr=2 interface=0 \
vendor=0x12d1 product=0x1003 devclass=0x00 devsubclass=0x00 \
sernum="" release=0x0000 intclass=0xff intsubclass=0xff \
ttyname=U0 ttyports=2 on uhub0
Note: serial/ufoma and net/uhso still provide port number and tty name
(uhso only) information through sysctls, which should now be removed.
Reviewed by: hpselasky
work properly with single-stepping in a kernel debugger. Specifically,
these routines have always disabled interrupts before increasing the nesting
count and restored the prior state of interrupts after decreasing the nesting
count to avoid problems with a nested interrupt not disabling interrupts
when acquiring a spin lock. However, trap interrupts for single-stepping
can still occur even when interrupts are disabled. Now the saved state of
interrupts is not saved in the thread until after interrupts have been
disabled and the nesting count has been increased. Similarly, the saved
state from the thread cannot be read once the nesting count has been
decreased to zero. To fix this, use temporary variables to store interrupt
state and shuffle it between the thread's MD area and the appropriate
registers.
In cooperation with: bde
MFC after: 1 month