- Initialize SMAPx registers too although they're unused in QEMU
- Do not pass IO/MEM resources to upper bus for activation, handle them locally.
Previously ACTIVATE method of upper bus was no-op so nothing bad
happened. But now FDT maps physaddr to vaddr and it causes
troubles: fdtbus_activate_resource resource assumes that
bustag/bushandle are already set which in this case is wrong.
which is presently: AES-XTS, no authentication. Create provider
with pagesize as sectorsize by default.
- Rewrite parsing code for geli(8)-backed swap options, now options
are required to be exact match, and unrecognized options will trigger
a warning.
- Don't initialize GELI device if it's already initialized. This
restores previous behavior.
- Don't duplicate file descriptor when working with geli(8) and
gbde(8) as there is no need to communicate with the utility other
than exit status.
- When calling swap_on_off_* routines, which_prog can only be SWAP_ON
or SWAP_OFF. Eliminate unneeded case branches by replacing switch
with if's.
- Plug a few memory leaks.
Reviewed by: hrs (but bugs are mine)
MFC after: 1 week
X-MFC-with: r252310, r252332, r252345
This occurs at RX DMA start, even though the RX FIFO has plenty of
space. I'll go figure out why, but this shouldn't cause people to
be spammed by these messages.
I missed to register zfs_ioc_jail and zfs_ioc_unjail as legacy ioctl's
with the new zfs_ioctl_register_legacy() function.
These operations do not modify pools or datasets so there is no need to
log them to pool history.
Reported by: Alexander Leidinger <ale@FreeBSD.org> and others on current@
MFC after: 3 days
r156418:
Don't set IN_CHANGE and IN_UPDATE on inodes for potentially suspended
file systems. This could cause deadlocks when creating snapshots.
(We can't do snapshots on ext2fs but it is useful to keep things in sync).
r183079:
- Only set i_offset in the parent directory's i-node during a lookup for
non-LOOKUP operations.
- Relax a VOP assertion for a DELETE lookup.
r187528:
Move the code from ufs_lookup.c used to do dotdot lookup, into
the helper function. It is supposed to be useful for any filesystem
that has to unlock dvp to walk to the ".." entry in lookup routine.
MFC after: 5 days
- Reconnect with some minor modifications, in particular now selsocket()
internals are adapted to use sbintime units after recent'ish calloutng
switch.
The filedesc lock may not be dropped unconditionally before exporting
fd to sbuf: fd might go away during execution. While it is ok for
DTYPE_VNODE and DTYPE_FIFO because the export is from a vrefed vnode
here, for other types it is unsafe.
Instead, drop the lock in export_fd_to_sb(), after preparing data in
memory and before writing to sbuf.
Spotted by: mjg
Suggested by: kib
Review by: kib
MFC after: 1 week
some general word-smithing.
- Don't claim that adaptive mutexes have a timeout (they don't).
- Don't treat pool mutexes as a separate primitive in a few places.
- Describe sleepable read-mostly locks as a separate lock type and add
them to the various tables.
- Don't claim that sx locks are less efficient. That hasn't been true in
a few years now.
- Describe lockmanager locks next to sx locks since they are very similar
in terms of rules, etc., and so that all the lock primitives are
grouped together before the non-lock primitives.
- Similarly, move the section on Giant after the description of all the
non-lock primitives to preserve grouping.
- Condition variables work on several types of locks, not just mutexes.
- Add a bit of language to compare/contrast condition variables with
sleep/wakeup.
- Add a note about why pause(9) is unique.
- Add some language to define bounded vs unbounded sleeps and explain
why they are treated separately (bounded sleeps only need CPU time
to make forward progress).
- Don't state that using mtx_sleep() is a bad idea. It is in fact rather
necessary.
- Rework the interaction table a bit. First, it did not include really
include sleepable rmlocks and it left out lockmgr entirely. To get
things to fit, combine similar lock types into the same column / row,
and explicitly state what "sleep" means. The notes about recursion
and lock order were also a bit banal (lock order is always important,
not just in the few places annotated here), so remove them. In
particular, the lock order note would need to be on just about every
cell. If we want to document recursion I think a better approach
would be a separate table summarizing the recursion rules for each
lock as having too many notes clutters the table.
- Tweak the tables to use less indentation so everything still fits with
the added columns.
- Correct a few cells in the context mode table.
- Use mdoc markup instead of explicit markup in a few places.
Requested by: julian
MFC after: 2 weeks
deadlkres was using a reversed test to check whether ticks had rolled over.
This meant that deadlkres could only fire after ticks had rolled over.
This test was actually unnecessary as deadlkres only ever took the
difference of ticks values which is safe even in the presence of ticks
rollover. Remove the tests entirely. Now deadlkres will properly fire
after a lock has been held after the timeout period.
MFC after: 1 month