this in awk using the hack of counting args of type off_t twice and args
of all other types once. This is too simple to work. It gave benignly
wrong results on alphas (off_t shouldn't be counted twice) and for
svr4_sys_mmap64() on i386's (off64_t should be counted twice). It gave
fatally wrong results for i386's with 64-bit longs (longs should be
counted twice). The correct value for sy_nargs is easier to determine
from the size of the args struct anyway, except for complications to
make the generated code almost readable.
Improved formatting of sysent tables by lining up the comments where
possible.
syscalls including exit(). These entries were unused, so the bugs had no
effect, but the the args struct tag will be used to calculate sy_nargs
correctly. exit() was wrong in all emulators.
to tcsh(1) upgrade. The following commands were added as builtins:
bindkey
builtins
complete
echotc
filetest
hup
log
ls-F
printenv
sched
settc
setty
telltc
uncomplete
where
The printf builtin was removed.
type. This gave an inconsistent amount of crufty padding on i386's with
64-bit longs (8 bytes instead of 4). On alphas it gives a consistent
amount of crufty padding (8 bytes) in addition to the 4 bytes of normal
padding caused by passing int args as register_t's.
Fixed the args struct tag for the NOPROTO syscalls (netbsd_lchown() and
netbsd_msync()). The tag is currently unused for NOPROTO syscalls, so
the bug has no effect, but it will be used even in the NOPROTO case to
calculate sy_nargs correctly.
Add a SA_QUIRK_NO_MODESEL type and use it for the OnStream real SCSI
device (not the broken one). This one is still broken in that it can't
be set to the same fixed block size it reports [ unflattering comments
about this company elided ].
If we're unable to set buffered mode on, complain, but drive on. It's
not a fatal error to not be in buffered mode.
like to see the true SRM bus number be passed to us, instead, we get FreeBSD's
PCI bus instance number (Brzzt! Wrong Answer!).
Also, once we've seen the MCPCIA that has the EISA bus on it, call
dec_kn300_cons_init just before configuring devices on this bus.
We'll call it later when, in the natural order of things, we configure
the MCPCIA that has the EISA bus that a serial console and/or VGA and/or
keyboard.
changes: consider a new PDB entry different if Class 3 service parameter
roles change (!!!). Do some checking as we're getting a port database
that traps whether things change while we're doing so. Handle N-port
and F-ports correctly. Fix the fabric login loop to retain a login/binding
if things haven't changed (I mean, why logout a device only to log it back
in). No longer accept, after fabric logins, garbage if we can't get a PDB
entry that matches the device we've just logged into- if it doesn't, log
it out as it is very unlikely to still be what we thought it was. Get rid
of some of the debounce loops because we could get stuck there.
Apparently the f/w has finished the command, but somehow an interrupt is
being lost. So, we just plain wedge when booting alphas.
This is a general routine we've needed for a while.