Literal references to /usr/local exist in a large number of files in
the FreeBSD base system. Many are in contributed software, in configuration
files, or in the documentation, but 19 uses have been identified in C
source files or headers outside the contrib and sys/contrib directories.
This commit makes it possible to set _PATH_LOCALBASE in paths.h to use
a different prefix for locally installed software.
In order to avoid changes to openssh source files, LOCALBASE is passed to
the build via Makefiles under src/secure. While _PATH_LOCALBASE could have
been used here, there is precedent in the construction of the path used to
a xauth program which depends on the LOCALBASE value passed on the compiler
command line to select a non-default directory.
This could be changed in a later commit to make the openssh build
consistently use _PATH_LOCALBASE. It is considered out-of-scope for this
commit.
Reviewed by: imp
MFC after: 1 month
Differential Revision: https://reviews.freebsd.org/D26942
headers. Device documentation often times give offsets relative to the
start of the entire VSEC, not just the post-header data area, so this
change makes it easier to correlate offsets.
Some ids are redundand because the list_ecaps() function decodes them
by explicit switch case. But listing them all makes it easier to not
miss ecaps, while not changing the functionality.
Initial submission by: Dmitry Luhtionov <dmitryluhtionov@gmail.com>
Sponsored by: The FreeBSD Foundation
MFC after: 3 days
command line option. Thanks to the removal of unnecessary information and
the organization into columns, this helps the output be more legible on
both 80 column displays and non-80 column displays. imp@ provided the
idea on this.
Parse out the VSEC. If the user invokes a second -c command line option,
do a hex dump of the vendor data.
Reviewed by: imp
MFC after: 3 days
Sponsored by: Intel
Differential Revision: http://reviews.freebsd.org/D22808
whitespace, and also reorder the fields so they are easier to read on
an 80 column display (the lines wrapped even before these changes).
Also fix non-standard nomenclature in the Caps code, and update the
man page.
Reported by: rpokala
standard nomenclature of "device" and "vendor" with the "sub" variants.
This changes the printed format, so anything that scrapes and parses
this will need to be adapted. No compatibility shims are provided,
but this will not be MFC'd.
Reviewed by: jhb, emaste, gtetlow
Approved by: jhb, emaste, gtetlow
This actually makes the rights requirements for accessing PCI config
space and BARs using /dev/pci same. Since unchanged /dev/pci mode
only allows write open for root, default configuration de-facto limits
the BAR read to root only. In particular, state-changing reads of the
registers are limited to root.
Discussed with: se
Suggested and reviewed by: jhb (kernel part)
Sponsored by: The FreeBSD Foundation
MFC after: 12 days
Differential revision: https://reviews.freebsd.org/D16580
Mainly focus on files that use BSD 2-Clause license, however the tool I
was using misidentified many licenses so this was mostly a manual - error
prone - task.
The Software Package Data Exchange (SPDX) group provides a specification
to make it easier for automated tools to detect and summarize well known
opensource licenses. We are gradually adopting the specification, noting
that the tags are considered only advisory and do not, in any way,
superceed or replace the license texts.
No functional change intended.
Mainly focus on files that use BSD 3-Clause license.
The Software Package Data Exchange (SPDX) group provides a specification
to make it easier for automated tools to detect and summarize well known
opensource licenses. We are gradually adopting the specification, noting
that the tags are considered only advisory and do not, in any way,
superceed or replace the license texts.
Special thanks to Wind River for providing access to "The Duke of
Highlander" tool: an older (2014) run over FreeBSD tree was useful as a
starting point.
The condition can be hit with simple user input, so it isn't an invariant.
Just error out.
PR: 217003
Reported by: Vladislav V. Prodan <admin at support.od.ua>
Sponsored by: Dell EMC Isilon
Reallow device selectors to have a trailing colon, as documented in the
manual page. This was broken along with some unrelated cleanups in
r295806.
PR: 215979
Reported by: David Boyd <David.Boyd49 at twc.com>
Sponsored by: Dell EMC Isilon
The interpretation of the Electromechanical Interlock Status was
inverted, so we disengaged the EI if a card was inserted.
Fix it to engage the EI if a card is inserted.
When displaying the slot capabilites/status with pciconf:
- We inverted the sense of the Power Controller Control bit,
saying the power was off when it was really on (according to
this bit). Fix that.
- Display the status of the Electromechanical Interlock:
EI(engaged)
EI(disengaged)
Reviewed by: jhb
MFC after: 3 days
Sponsored by: Dell Inc.
Differential Revision: https://reviews.freebsd.org/D7426
- Group the output so that it follows the capability register set more
closely. The first line now contains device information and the
second line contains link information. As a result, ARI status is now
output on the first line, and the link width is moved down to the second
line of link information.
- Only read the DEVICE_CAP2 register to check for ARI if the capability
version is >= 2.
- Don't output any link information if the link capability and status
registers are zero.
- Label the MSI interrupt index value as "MSI" instead of "IRQ".
Some invalid PCI device selectors could cause read access to an initialized
variable next to the array (local loop index variable).
While here, the parser has been made more strict with regard to the syntax
of PCI device selectors as documented in the man-page. E.g. "pci:" used to
be interpreted as "pci0:0".
MFC after: 3 days
bridges. Currently this includes information about what resources a
bridge decodes on the upstream side for use by downstream devices including
bus numbers, I/O port resources, and memory resources. Windows and bus
ranges are enumerated for both PCI-PCI bridges and PCI-CardBus bridges.
To simplify the implementation, all enumeration is done by reading the
appropriate config space registers directly rather than querying the
bridge driver in the kernel via new ioctls. This does result in a few
limitations.
First, an unimplemented window in a PCI-PCI bridge cannot be accurately
detected as accurate detection requires writing to the window base
register. That is not safe for pciconf(8). Instead, this assumes that
any window where both the base and limit read as all zeroes is
unimplemented.
Second, the PCI-PCI bridge driver in a tree has a few quirks for
PCI-PCI bridges that use subtractive decoding but do not indicate that
via the progif config register. The list of quirks is duplicated in
pciconf's source.
Reviewed by: imp
MFC after: 2 weeks
Differential Revision: https://reviews.freebsd.org/D4171
Given the pciids database on ports is updated more often than the one in base
prefer this version if present, otherwise read the one from base.
MFC after: 1 week
Relnotes: yes
Differential Revision: https://reviews.freebsd.org/D3391
Off by default, build behaves normally.
WITH_META_MODE we get auto objdir creation, the ability to
start build from anywhere in the tree.
Still need to add real targets under targets/ to build packages.
Differential Revision: D2796
Reviewed by: brooks imp
usr.sbin/pciconf/pciconf.c:237:12: error: address of array 'p->pd_name' will
always evaluate to 'true' [-Werror,-Wpointer-bool-conversion]
(p->pd_name && *p->pd_name) ? p->pd_name :
~~~^~~~~~~ ~~
usr.sbin/pciconf/pciconf.c:239:12: error: address of array 'p->pd_name' will
always evaluate to 'true' [-Werror,-Wpointer-bool-conversion]
(p->pd_name && *p->pd_name) ? (int)p->pd_unit :
~~~^~~~~~~ ~~
The pd_name field of struct pci_conf is an array, so it can never be null.
Remove the unnecessary check.
an error if the argument to pciconf -a doesn't have a unit number, rather
than triggering an assertion failure.
PR: 194506
Reported by: Anthony Cornehl <accornehl@gmail.com>
Sponsored by: EMC / Isilon Storage Division
Teach pciconf how to print out the status (enabled/disabled) of the ARI
capability on PCI Root Complexes and Downstream Ports.
MFC after: 2 months
Sponsored by: Sandvine Inc.