This patch removes KR PHY reset from ixgbe_init_phy_ops_X550em. Since
this function is meant to initialize function pointers for detected PHY
type. Internal PHY reset was moved to ixgbe_setup_internal_phy_t_x550em
which will now detect which mode does internal PHY work in, and setup it
as required.