d4f954b166
Fixes: 211f9a9ce2
("enic: add guide")
Cc: stable@dpdk.org
Signed-off-by: John Daley <johndale@cisco.com>
Acked-by: John McNamara <john.mcnamara@intel.com>
383 lines
15 KiB
ReStructuredText
383 lines
15 KiB
ReStructuredText
.. BSD LICENSE
|
|
Copyright (c) 2017, Cisco Systems, Inc.
|
|
All rights reserved.
|
|
|
|
Redistribution and use in source and binary forms, with or without
|
|
modification, are permitted provided that the following conditions
|
|
are met:
|
|
|
|
1. Redistributions of source code must retain the above copyright
|
|
notice, this list of conditions and the following disclaimer.
|
|
|
|
2. Redistributions in binary form must reproduce the above copyright
|
|
notice, this list of conditions and the following disclaimer in
|
|
the documentation and/or other materials provided with the
|
|
distribution.
|
|
|
|
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
|
|
"AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
|
|
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
|
|
FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
|
|
COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
|
|
INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
|
|
BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
|
|
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
|
|
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
|
|
LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
|
|
ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
|
|
POSSIBILITY OF SUCH DAMAGE.
|
|
|
|
ENIC Poll Mode Driver
|
|
=====================
|
|
|
|
ENIC PMD is the DPDK poll-mode driver for the Cisco System Inc. VIC Ethernet
|
|
NICs. These adapters are also referred to as vNICs below. If you are running
|
|
or would like to run DPDK software applications on Cisco UCS servers using
|
|
Cisco VIC adapters the following documentation is relevant.
|
|
|
|
How to obtain ENIC PMD integrated DPDK
|
|
--------------------------------------
|
|
|
|
ENIC PMD support is integrated into the DPDK suite. dpdk-<version>.tar.gz
|
|
should be downloaded from http://dpdk.org
|
|
|
|
|
|
Configuration information
|
|
-------------------------
|
|
|
|
- **DPDK Configuration Parameters**
|
|
|
|
The following configuration options are available for the ENIC PMD:
|
|
|
|
- **CONFIG_RTE_LIBRTE_ENIC_PMD** (default y): Enables or disables inclusion
|
|
of the ENIC PMD driver in the DPDK compilation.
|
|
|
|
- **CONFIG_RTE_LIBRTE_ENIC_DEBUG** (default n): Enables or disables debug
|
|
logging within the ENIC PMD driver.
|
|
|
|
- **vNIC Configuration Parameters**
|
|
|
|
- **Number of Queues**
|
|
|
|
The maximum number of receive queues (RQs), work queues (WQs) and
|
|
completion queues (CQs) are configurable on a per vNIC basis
|
|
through the Cisco UCS Manager (CIMC or UCSM).
|
|
|
|
These values should be configured as follows:
|
|
|
|
- The number of WQs should be greater or equal to the value of the
|
|
expected nb_tx_q parameter in the call to the
|
|
rte_eth_dev_configure()
|
|
|
|
- The number of RQs configured in the vNIC should be greater or
|
|
equal to *twice* the value of the expected nb_rx_q parameter in
|
|
the call to rte_eth_dev_configure(). With the addition of Rx
|
|
scatter, a pair of RQs on the vnic is needed for each receive
|
|
queue used by DPDK, even if Rx scatter is not being used.
|
|
Having a vNIC with only 1 RQ is not a valid configuration, and
|
|
will fail with an error message.
|
|
|
|
- The number of CQs should set so that there is one CQ for each
|
|
WQ, and one CQ for each pair of RQs.
|
|
|
|
For example: If the application requires 3 Rx queues, and 3 Tx
|
|
queues, the vNIC should be configured to have at least 3 WQs, 6
|
|
RQs (3 pairs), and 6 CQs (3 for use by WQs + 3 for use by the 3
|
|
pairs of RQs).
|
|
|
|
- **Size of Queues**
|
|
|
|
Likewise, the number of receive and transmit descriptors are configurable on
|
|
a per vNIC bases via the UCS Manager and should be greater than or equal to
|
|
the nb_rx_desc and nb_tx_desc parameters expected to be used in the calls
|
|
to rte_eth_rx_queue_setup() and rte_eth_tx_queue_setup() respectively.
|
|
An application requesting more than the set size will be limited to that
|
|
size.
|
|
|
|
Unless there is a lack of resources due to creating many vNICs, it
|
|
is recommended that the WQ and RQ sizes be set to the maximum. This
|
|
gives the application the greatest amount of flexibility in its
|
|
queue configuration.
|
|
|
|
- *Note*: Since the introduction of Rx scatter, for performance
|
|
reasons, this PMD uses two RQs on the vNIC per receive queue in
|
|
DPDK. One RQ holds descriptors for the start of a packet the
|
|
second RQ holds the descriptors for the rest of the fragments of
|
|
a packet. This means that the nb_rx_desc parameter to
|
|
rte_eth_rx_queue_setup() can be a greater than 4096. The exact
|
|
amount will depend on the size of the mbufs being used for
|
|
receives, and the MTU size.
|
|
|
|
For example: If the mbuf size is 2048, and the MTU is 9000, then
|
|
receiving a full size packet will take 5 descriptors, 1 from the
|
|
start of packet queue, and 4 from the second queue. Assuming
|
|
that the RQ size was set to the maximum of 4096, then the
|
|
application can specify up to 1024 + 4096 as the nb_rx_desc
|
|
parameter to rte_eth_rx_queue_setup().
|
|
|
|
- **Interrupts**
|
|
|
|
Only one interrupt per vNIC interface should be configured in the UCS
|
|
manager regardless of the number receive/transmit queues. The ENIC PMD
|
|
uses this interrupt to get information about link status and errors
|
|
in the fast path.
|
|
|
|
.. _enic-flow-director:
|
|
|
|
Flow director support
|
|
---------------------
|
|
|
|
Advanced filtering support was added to 1300 series VIC firmware starting
|
|
with version 2.0.13 for C-series UCS servers and version 3.1.2 for UCSM
|
|
managed blade servers. In order to enable advanced filtering the 'Advanced
|
|
filter' radio button should be enabled via CIMC or UCSM followed by a reboot
|
|
of the server.
|
|
|
|
With advanced filters, perfect matching of all fields of IPv4, IPv6 headers
|
|
as well as TCP, UDP and SCTP L4 headers is available through flow director.
|
|
Masking of these fields for partial match is also supported.
|
|
|
|
Without advanced filter support, the flow director is limited to IPv4
|
|
perfect filtering of the 5-tuple with no masking of fields supported.
|
|
|
|
SR-IOV mode utilization
|
|
-----------------------
|
|
|
|
UCS blade servers configured with dynamic vNIC connection policies in UCS
|
|
manager are capable of supporting assigned devices on virtual machines (VMs)
|
|
through a KVM hypervisor. Assigned devices, also known as 'passthrough'
|
|
devices, are SR-IOV virtual functions (VFs) on the host which are exposed
|
|
to VM instances.
|
|
|
|
The Cisco Virtual Machine Fabric Extender (VM-FEX) gives the VM a dedicated
|
|
interface on the Fabric Interconnect (FI). Layer 2 switching is done at
|
|
the FI. This may eliminate the requirement for software switching on the
|
|
host to route intra-host VM traffic.
|
|
|
|
Please refer to `Creating a Dynamic vNIC Connection Policy
|
|
<http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/vm_fex/vmware/gui/config_guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide_chapter_010.html#task_433E01651F69464783A68E66DA8A47A5>`_
|
|
for information on configuring SR-IOV Adapter policies using UCS manager.
|
|
|
|
Once the policies are in place and the host OS is rebooted, VFs should be
|
|
visible on the host, E.g.:
|
|
|
|
.. code-block:: console
|
|
|
|
# lspci | grep Cisco | grep Ethernet
|
|
0d:00.0 Ethernet controller: Cisco Systems Inc VIC Ethernet NIC (rev a2)
|
|
0d:00.1 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
|
|
0d:00.2 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
|
|
0d:00.3 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
|
|
0d:00.4 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
|
|
0d:00.5 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
|
|
0d:00.6 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
|
|
0d:00.7 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
|
|
|
|
Enable Intel IOMMU on the host and install KVM and libvirt. A VM instance should
|
|
be created with an assigned device. When using libvirt, this configuration can
|
|
be done within the domain (i.e. VM) config file. For example this entry maps
|
|
host VF 0d:00:01 into the VM.
|
|
|
|
.. code-block:: console
|
|
|
|
<interface type='hostdev' managed='yes'>
|
|
<mac address='52:54:00:ac:ff:b6'/>
|
|
<source>
|
|
<address type='pci' domain='0x0000' bus='0x0d' slot='0x00' function='0x1'/>
|
|
</source>
|
|
|
|
Alternatively, the configuration can be done in a separate file using the
|
|
``network`` keyword. These methods are described in the libvirt documentation for
|
|
`Network XML format <https://libvirt.org/formatnetwork.html>`_.
|
|
|
|
When the VM instance is started, the ENIC KVM driver will bind the host VF to
|
|
vfio, complete provisioning on the FI and bring up the link.
|
|
|
|
.. note::
|
|
|
|
It is not possible to use a VF directly from the host because it is not
|
|
fully provisioned until the hypervisor brings up the VM that it is assigned
|
|
to.
|
|
|
|
In the VM instance, the VF will now be visible. E.g., here the VF 00:04.0 is
|
|
seen on the VM instance and should be available for binding to a DPDK.
|
|
|
|
.. code-block:: console
|
|
|
|
# lspci | grep Ether
|
|
00:04.0 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
|
|
|
|
Follow the normal DPDK install procedure, binding the VF to either ``igb_uio``
|
|
or ``vfio`` in non-IOMMU mode.
|
|
|
|
Please see :ref:`Limitations <enic_limitations>` for limitations in
|
|
the use of SR-IOV.
|
|
|
|
.. _enic_limitations:
|
|
|
|
Limitations
|
|
-----------
|
|
|
|
- **VLAN 0 Priority Tagging**
|
|
|
|
If a vNIC is configured in TRUNK mode by the UCS manager, the adapter will
|
|
priority tag egress packets according to 802.1Q if they were not already
|
|
VLAN tagged by software. If the adapter is connected to a properly configured
|
|
switch, there will be no unexpected behavior.
|
|
|
|
In test setups where an Ethernet port of a Cisco adapter in TRUNK mode is
|
|
connected point-to-point to another adapter port or connected though a router
|
|
instead of a switch, all ingress packets will be VLAN tagged. Programs such
|
|
as l3fwd which do not account for VLAN tags in packets will misbehave. The
|
|
solution is to enable VLAN stripping on ingress. The follow code fragment is
|
|
example of how to accomplish this:
|
|
|
|
.. code-block:: console
|
|
|
|
vlan_offload = rte_eth_dev_get_vlan_offload(port);
|
|
vlan_offload |= ETH_VLAN_STRIP_OFFLOAD;
|
|
rte_eth_dev_set_vlan_offload(port, vlan_offload);
|
|
|
|
- Limited flow director support on 1200 series and 1300 series Cisco VIC
|
|
adapters with old firmware. Please see :ref:`enic-flow-director`.
|
|
|
|
- Flow director features are not supported on generation 1 Cisco VIC adapters
|
|
(M81KR and P81E)
|
|
|
|
- **SR-IOV**
|
|
|
|
- KVM hypervisor support only. VMware has not been tested.
|
|
- Requires VM-FEX, and so is only available on UCS managed servers connected
|
|
to Fabric Interconnects. It is not on standalone C-Series servers.
|
|
- VF devices are not usable directly from the host. They can only be used
|
|
as assigned devices on VM instances.
|
|
- Currently, unbind of the ENIC kernel mode driver 'enic.ko' on the VM
|
|
instance may hang. As a workaround, enic.ko should blacklisted or removed
|
|
from the boot process.
|
|
- pci_generic cannot be used as the uio module in the VM. igb_uio or
|
|
vfio in non-IOMMU mode can be used.
|
|
- The number of RQs in UCSM dynamic vNIC configurations must be at least 2.
|
|
- The number of SR-IOV devices is limited to 256. Components on target system
|
|
might limit this number to fewer than 256.
|
|
|
|
How to build the suite
|
|
----------------------
|
|
|
|
Refer to the document :ref:`compiling and testing a PMD for a NIC
|
|
<pmd_build_and_test>` for details.
|
|
|
|
By default the ENIC PMD library will be built into the DPDK library.
|
|
|
|
For configuring and using UIO and VFIO frameworks, please refer to the
|
|
documentation that comes with DPDK suite.
|
|
|
|
Supported Cisco VIC adapters
|
|
----------------------------
|
|
|
|
ENIC PMD supports all recent generations of Cisco VIC adapters including:
|
|
|
|
- VIC 1280
|
|
- VIC 1240
|
|
- VIC 1225
|
|
- VIC 1285
|
|
- VIC 1225T
|
|
- VIC 1227
|
|
- VIC 1227T
|
|
- VIC 1380
|
|
- VIC 1340
|
|
- VIC 1385
|
|
- VIC 1387
|
|
|
|
Supported Operating Systems
|
|
---------------------------
|
|
|
|
Any Linux distribution fulfilling the conditions described in Dependencies
|
|
section of DPDK documentation.
|
|
|
|
Supported features
|
|
------------------
|
|
|
|
- Unicast, multicast and broadcast transmission and reception
|
|
- Receive queue polling
|
|
- Port Hardware Statistics
|
|
- Hardware VLAN acceleration
|
|
- IP checksum offload
|
|
- Receive side VLAN stripping
|
|
- Multiple receive and transmit queues
|
|
- Flow Director ADD, UPDATE, DELETE, STATS operation support IPv4 and IPv6
|
|
- Promiscuous mode
|
|
- Setting RX VLAN (supported via UCSM/CIMC only)
|
|
- VLAN filtering (supported via UCSM/CIMC only)
|
|
- Execution of application by unprivileged system users
|
|
- IPV4, IPV6 and TCP RSS hashing
|
|
- Scattered Rx
|
|
- MTU update
|
|
- SR-IOV on UCS managed servers connected to Fabric Interconnects.
|
|
|
|
Known bugs and unsupported features in this release
|
|
---------------------------------------------------
|
|
|
|
- Signature or flex byte based flow direction
|
|
- Drop feature of flow direction
|
|
- VLAN based flow direction
|
|
- non-IPV4 flow direction
|
|
- Setting of extended VLAN
|
|
- UDP RSS hashing
|
|
- MTU update only works if Scattered Rx mode is disabled
|
|
|
|
Prerequisites
|
|
-------------
|
|
|
|
- Prepare the system as recommended by DPDK suite. This includes environment
|
|
variables, hugepages configuration, tool-chains and configuration
|
|
- Insert vfio-pci kernel module using the command 'modprobe vfio-pci' if the
|
|
user wants to use VFIO framework
|
|
- Insert uio kernel module using the command 'modprobe uio' if the user wants
|
|
to use UIO framework
|
|
- DPDK suite should be configured based on the user's decision to use VFIO or
|
|
UIO framework
|
|
- If the vNIC device(s) to be used is bound to the kernel mode Ethernet driver
|
|
use 'ifconfig' to bring the interface down. The dpdk-devbind.py tool can
|
|
then be used to unbind the device's bus id from the ENIC kernel mode driver.
|
|
- Bind the intended vNIC to vfio-pci in case the user wants ENIC PMD to use
|
|
VFIO framework using dpdk-devbind.py.
|
|
- Bind the intended vNIC to igb_uio in case the user wants ENIC PMD to use
|
|
UIO framework using dpdk-devbind.py.
|
|
|
|
At this point the system should be ready to run DPDK applications. Once the
|
|
application runs to completion, the vNIC can be detached from vfio-pci or
|
|
igb_uio if necessary.
|
|
|
|
Root privilege is required to bind and unbind vNICs to/from VFIO/UIO.
|
|
VFIO framework helps an unprivileged user to run the applications.
|
|
For an unprivileged user to run the applications on DPDK and ENIC PMD,
|
|
it may be necessary to increase the maximum locked memory of the user.
|
|
The following command could be used to do this.
|
|
|
|
.. code-block:: console
|
|
|
|
sudo sh -c "ulimit -l <value in Kilo Bytes>"
|
|
|
|
The value depends on the memory configuration of the application, DPDK and
|
|
PMD. Typically, the limit has to be raised to higher than 2GB.
|
|
e.g., 2621440
|
|
|
|
The compilation of any unused drivers can be disabled using the
|
|
configuration file in config/ directory (e.g., config/common_linuxapp).
|
|
This would help in bringing down the time taken for building the
|
|
libraries and the initialization time of the application.
|
|
|
|
Additional Reference
|
|
--------------------
|
|
|
|
- http://www.cisco.com/c/en/us/products/servers-unified-computing
|
|
|
|
Contact Information
|
|
-------------------
|
|
|
|
Any questions or bugs should be reported to DPDK community and to the ENIC PMD
|
|
maintainers:
|
|
|
|
- John Daley <johndale@cisco.com>
|
|
- Nelson Escobar <neescoba@cisco.com>
|