As of r313097, the HotPlug code requires the link to support
reporting of the data-link status. Remove tests for this capability
from code that can now assume its presence.
Suggested by: jhb
Reviewed by: jhb
MFC after: 3 days
Sponsored by: Dell EMC
Differential Revision: https://reviews.freebsd.org/D9431
Some PCI-e bridges report that they support HotPlug in the slot
capabilities but do not report support for Data Layer Active events
in the link capabilities register. These bridges do not work correctly
when HotPlug is used. Further, while the description of HotPlug in
the spec does not mention that DL active events are required, the
description of the link capabilities register says that DL active is
required for HotPlug. Thanks to Dave Baukus for finding that language
in the spec.
PR: 211699
Submitted by: Dave Baukus <daveb@spectralogic.com>
Reviewed by: vangyzen
MFC after: 3 days
Some devices report that they have an MRL when they actually
do not. Since they always report that the MRL is open, child
devices would be ignored. Try to detect these devices and
ignore their claim of HotPlug support. Specifically,
if there is an open MRL but the Data Link Layer is active,
the MRL is not real.
Revert r303645 to re-enable HotPlug support for slots with
power controllers, since it works correctly in my testing.
Start the DLL state-change timer if Presence /or/ MRL state changes,
along with other conditions. Previously, we started the timer iff
Presence changed. If there is an MRL, it must be closed for power
to be turned on, so Presence is unlikely to change on an MRL-close event.
Add a printf() of interesting registers on HotPlug interrupts and
commands (one from erj@). These were very useful for debugging.
Guard them with bootverbose, since they're spam in normal operation.
In collaboration with: jhb
Reviewed by: jhb
MFC after: 1 day
Relnotes: yes (re-enable HotPlug support for slots with power controllers)
Sponsored by: Dell Inc.
Differential Revision: https://reviews.freebsd.org/D7509
The interpretation of the Electromechanical Interlock Status was
inverted, so we disengaged the EI if a card was inserted.
Fix it to engage the EI if a card is inserted.
When displaying the slot capabilites/status with pciconf:
- We inverted the sense of the Power Controller Control bit,
saying the power was off when it was really on (according to
this bit). Fix that.
- Display the status of the Electromechanical Interlock:
EI(engaged)
EI(disengaged)
Reviewed by: jhb
MFC after: 3 days
Sponsored by: Dell Inc.
Differential Revision: https://reviews.freebsd.org/D7426
After further review of the spec, I do not think the current HotPlug
code handles slots with power controllers correctly. In particular,
the power state of the slot is to be inferred from other events, not
from examining the state of the power control bit in SLOT_CTL. For now,
disable PCI hotplug support on such slots.
PR: 211081
Tested by: Jeffrey E Pieper <jeffrey.e.pieper@intel.com>
MFC after: 3 days
Some systems and/or devices (such as riser cards) do not include a
non-compliant implementation of PCI-e HotPlug that can result in devices
not being attached (e.g. the HotPlug code might assume that a card is
being unplugged and will power the slot off and detach it). This
tunable can be set to 0 to disable support for PCI-e HotPlug ignoring
the incorrect HotPlug state on these slots.
PR: 211081
Reported by: Sergey Renkas <serg_ic@mail.ru> (SuperMicro X7 riser card)
Reported by: Jeffrey E Pieper <jeffrey.e.pieper@intel.com>
(Intel X520 adapter)
MFC after: 1 week
Relnotes: yes
- Add a pcib_detach() function for the PCI-PCI bridge driver. It
tears down the NEW_PCIB and hotplug state including destroying
resource managers, deleting child devices, and disabling hotplug
events.
- Add a detach method to the ACPI PCI-PCI bridge driver which calls
pcib_detach() and then frees the copy of the _PRT interrupt routing
table.
- Add a detach method to the PCI-Cardbus bridge driver which frees
the PCI bus resources in addition to calling cbb_detach().
- Explicitly clear any pending hotplug events during attach to ensure
future events will generate an interrupt.
- If a the Command Completed bit is set in the slot status register
when the command completion timeout fires, treat it as if the
command completed and the completion interrupt was just lost rather
than forcing a detach.
- Don't wait for a Command Completed notification if Command Completion
interrupts are disabled. The spec explicitly says no interrupt is
enabled when clearing CCIE, and on my T400 no interrupt is generated
when CCIE is changed from cleared to set, either. In addition, the
T400 doesn't appear to set the Command Completed bit in the cases
where it doesn't generate an interrupt, so don't schedule the timer
either. (If the CC bit were always set, one could always set the timer
and rely on the logic of treating CC set as a missed interrupt.)
Reviewed by: imp (older version)
Differential Revision: https://reviews.freebsd.org/D6424
Previously the command completion interrupt would post any pending
command immediately before pcib_pcie_hotplug_update() had been
run to inspect the current status. Now, the command completion
interrupt merely clears the flag and stops the timer assuming that
the caller is always going to call pcib_pcie_hotplug_update() to
generate the next hotplug command if one is needed.
While here, fix a bug for systems with command completion where the
old (existing) value was written to the slot control register instead
of the new value. This fixes the complaint about a missing hotplug
interrupt on my T400.
Differential Revision: https://reviews.freebsd.org/D6363
translate the pci rid to a controller ID. The translation could be based
on the 'msi-map' OFW property, a similar ACPI option, or hard-coded for
hardware lacking the above options.
Reviewed by: wma
Obtained from: ABT Systems Ltd
Sponsored by: The FreeBSD Foundation
Add a new get_id interface to pci and pcib. This will allow us to both
detect failures, and get different PCI IDs.
For the former the interface returns an int to signal an error. The ID is
returned at a uintptr_t * argument.
For the latter there is a type argument that allows selecting the ID type.
This only specifies a single type, however a MSI type will be added
to handle the need to find the ID the hardware passes to the ARM GICv3
interrupt controller.
A follow up commit will be made to remove pci_get_rid.
Reviewed by: jhb, rstone (previous version)
Obtained from: ABT Systems Ltd
Sponsored by: The FreeBSD Foundation
Differential Revision: https://reviews.freebsd.org/D6239
detect failures, and get different PCI IDs.
For the former the interface returns an int to signal an error. The ID is
returned at a uintptr_t * argument.
For the latter there is a type argument that allows selecting the ID type.
This only specifies a single type, however a MSI type will be added
to handle the need to find the ID the hardware passes to the ARM GICv3
interrupt controller.
A follow up commit will be made to remove pci_get_rid.
Reviewed by: jhb, rstone
Obtained from: ABT Systems Ltd
Sponsored by: The FreeBSD Foundation
Differential Revision: https://reviews.freebsd.org/D6239
PCI-express HotPlug support is implemented via bits in the slot
registers of the PCI-express capability of the downstream port along
with an interrupt that triggers when bits in the slot status register
change.
This is implemented for FreeBSD by adding HotPlug support to the
PCI-PCI bridge driver which attaches to the virtual PCI-PCI bridges
representing downstream ports on HotPlug slots. The PCI-PCI bridge
driver registers an interrupt handler to receive HotPlug events. It
also uses the slot registers to determine the current HotPlug state
and drive an internal HotPlug state machine. For simplicty of
implementation, the PCI-PCI bridge device detaches and deletes the
child PCI device when a card is removed from a slot and creates and
attaches a PCI child device when a card is inserted into the slot.
The PCI-PCI bridge driver provides a bus_child_present which claims
that child devices are present on HotPlug-capable slots only when a
card is inserted. Rather than requiring a timeout in the RC for
config accesses to not-present children, the pcib_read/write_config
methods fail all requests when a card is not present (or not yet
ready).
These changes include support for various optional HotPlug
capabilities such as a power controller, mechanical latch,
electro-mechanical interlock, indicators, and an attention button.
It also includes support for devices which require waiting for
command completion events before initiating a subsequent HotPlug
command. However, it has only been tested on ExpressCard systems
which support surprise removal and have none of these optional
capabilities.
PCI-express HotPlug support is conditional on the PCI_HP option
which is enabled by default on arm64, x86, and powerpc.
Reviewed by: adrian, imp, vangyzen (older versions)
Relnotes: yes
Differential Revision: https://reviews.freebsd.org/D6136
This allows the PCI-PCI bridge driver to save a reference to the child
device in its softc.
Note that this required moving the "pci" device creation out of
acpi_pcib_attach(). Instead, acpi_pcib_attach() is renamed to
acpi_pcib_fetch_prt() as it's sole action now is to fetch the PCI
interrupt routing table.
Differential Revision: https://reviews.freebsd.org/D6021
On some architectures, u_long isn't large enough for resource definitions.
Particularly, powerpc and arm allow 36-bit (or larger) physical addresses, but
type `long' is only 32-bit. This extends rman's resources to uintmax_t. With
this change, any resource can feasibly be placed anywhere in physical memory
(within the constraints of the driver).
Why uintmax_t and not something machine dependent, or uint64_t? Though it's
possible for uintmax_t to grow, it's highly unlikely it will become 128-bit on
32-bit architectures. 64-bit architectures should have plenty of RAM to absorb
the increase on resource sizes if and when this occurs, and the number of
resources on memory-constrained systems should be sufficiently small as to not
pose a drastic overhead. That being said, uintmax_t was chosen for source
clarity. If it's specified as uint64_t, all printf()-like calls would either
need casts to uintmax_t, or be littered with PRI*64 macros. Casts to uintmax_t
aren't horrible, but it would also bake into the API for
resource_list_print_type() either a hidden assumption that entries get cast to
uintmax_t for printing, or these calls would need the PRI*64 macros. Since
source code is meant to be read more often than written, I chose the clearest
path of simply using uintmax_t.
Tested on a PowerPC p5020-based board, which places all device resources in
0xfxxxxxxxx, and has 8GB RAM.
Regression tested on qemu-system-i386
Regression tested on qemu-system-mips (malta profile)
Tested PAE and devinfo on virtualbox (live CD)
Special thanks to bz for his testing on ARM.
Reviewed By: bz, jhb (previous)
Relnotes: Yes
Sponsored by: Alex Perez/Inertial Computing
Differential Revision: https://reviews.freebsd.org/D4544
Summary:
The idea behind this is '~0ul' is well-defined, and casting to uintmax_t, on a
32-bit platform, will leave the upper 32 bits as 0. The maximum range of a
resource is 0xFFF.... (all bits of the full type set). By dropping the 'ul'
suffix, C type promotion rules apply, and the sign extension of ~0 on 32 bit
platforms gets it to a type-independent 'unsigned max'.
Reviewed By: cem
Sponsored by: Alex Perez/Inertial Computing
Differential Revision: https://reviews.freebsd.org/D5255
Most calls to bus_alloc_resource() use "anywhere" as the range, with a given
count. Migrate these to use the new bus_alloc_resource_anywhere() API.
Reviewed by: jhb
Differential Revision: https://reviews.freebsd.org/D5370
Summary:
Migrate to using the semi-opaque type rman_res_t to specify rman resources. For
now, this is still compatible with u_long.
This is step one in migrating rman to use uintmax_t for resources instead of
u_long.
Going forward, this could feasibly be used to specify architecture-specific
definitions of resource ranges, rather than baking a specific integer type into
the API.
This change has been broken out to facilitate MFC'ing drivers back to 10 without
breaking ABI.
Reviewed By: jhb
Sponsored by: Alex Perez/Inertial Computing
Differential Revision: https://reviews.freebsd.org/D5075
When the system has more than a single PCI domain, the bus numbers
are not unique, thus they cannot be used for "pci" device numbering.
Change bus numbers to -1 (i.e. to-be-determined automatically)
wherever the code did not care about domains.
Reviewed by: jhb
Obtained from: Semihalf
Sponsored by: The FreeBSD Foundation
Differential Revision: https://reviews.freebsd.org/D3406
Internal bridges in Cavium ThunderX SoC behave as subtractive,
but they are unable to be identified. Force setting an appropriate
flag.
Reviewed by: emaste, imp
Obtained from: Semihalf
Sponsored by: The FreeBSD Foundation
Differential Revision: https://reviews.freebsd.org/D3277
(easily) without having to go to other drivers to change the
magical return values. This wouldn't be so bad if there were
proper defines for these constants.
In particular dev/acpica/acpi_pcib_pci.c returns -1000 as the
probe priority and it's expected that this driver gets to
attach over the common PCI bus drivers.
BUS_PROBE_HOOVER is. Drivers like proto(4), when compiled into the
kernel or preloaded, will render your system useless by virtue of
attaching to your PCI busses.
Return BUS_PROBE_GENERIC instead. It's just the next priority up
from BUS_PROBE_HOOVER. No other meaning has been give to its use.
While BUS_PROBE_DEFAULT seems like a better candidate, it's hard
not to think that there must be some reason why these drivers
return -10000 in the first place.
Differential Revision: D2705
Summary:
The Freescale PCIe Root Complex shows up as a Processor class device, PowerPC
subclass, so the generic PCI code ignores it for a bridge. This adds support
for it.
As part of this, update the Freescale PCI hostbridge driver, to allow probing
beyond the root complex, instead of only allowing "proper" PCI-PCI bridges.
Reviewers: #powerpc, marcel, nwhitehorn
Reviewed By: nwhitehorn
Subscribers: imp
Differential Revision: https://reviews.freebsd.org/D2442
Relnotes: yes
(type 1 and type 2) as well as leaf devices (type 0). In particular,
this allows the existing PCI bus logic to save and restore capability
registers such as MSI and PCI-express work for bridge devices rather than
requiring that code to be duplicated in bridge drivers. It also means
that bridge drivers no longer need to save and restore basic registers
such as the PCI command register or BARs nor manage powerstates for the
bridge device.
While here, pci_setup_secbus() has been changed to initialize the 'sec'
and 'sub' fields in the 'secbus' structure instead of requiring the pcib
and pccbb drivers to do this in the NEW_PCIB + PCI_RES_BUS case.
Differential Revision: https://reviews.freebsd.org/D2240
Reviewed by: imp, jmg
MFC after: 2 weeks
driver's suspend and resume routines. These have been redundant no-ops
since r214065 changed the PCI bus driver to manage power states for
all devices (including type 1/2 bridge devices) during suspend and resume.
in userland rename in-kernel getenv()/setenv() to kern_setenv()/kern_getenv().
This fixes a namespace collision with libc symbols.
Submitted by: kmacy
Tested by: make universe
These changes prevent sysctl(8) from returning proper output,
such as:
1) no output from sysctl(8)
2) erroneously returning ENOMEM with tools like truss(1)
or uname(1)
truss: can not get etype: Cannot allocate memory
there is an environment variable which shall initialize the SYSCTL
during early boot. This works for all SYSCTL types both statically and
dynamically created ones, except for the SYSCTL NODE type and SYSCTLs
which belong to VNETs. A new flag, CTLFLAG_NOFETCH, has been added to
be used in the case a tunable sysctl has a custom initialisation
function allowing the sysctl to still be marked as a tunable. The
kernel SYSCTL API is mostly the same, with a few exceptions for some
special operations like iterating childrens of a static/extern SYSCTL
node. This operation should probably be made into a factored out
common macro, hence some device drivers use this. The reason for
changing the SYSCTL API was the need for a SYSCTL parent OID pointer
and not only the SYSCTL parent OID list pointer in order to quickly
generate the sysctl path. The motivation behind this patch is to avoid
parameter loading cludges inside the OFED driver subsystem. Instead of
adding special code to the OFED driver subsystem to post-load tunables
into dynamically created sysctls, we generalize this in the kernel.
Other changes:
- Corrected a possibly incorrect sysctl name from "hw.cbb.intr_mask"
to "hw.pcic.intr_mask".
- Removed redundant TUNABLE statements throughout the kernel.
- Some minor code rewrites in connection to removing not needed
TUNABLE statements.
- Added a missing SYSCTL_DECL().
- Wrapped two very long lines.
- Avoid malloc()/free() inside sysctl string handling, in case it is
called to initialize a sysctl from a tunable, hence malloc()/free() is
not ready when sysctls from the sysctl dataset are registered.
- Bumped FreeBSD version to indicate SYSCTL API change.
MFC after: 2 weeks
Sponsored by: Mellanox Technologies
PCIe Alternate RID Interpretation (ARI) is an optional feature that
allows devices to have up to 256 different functions. It is
implemented by always setting the PCI slot number to 0 and
re-purposing the 5 bits used to encode the slot number to instead
contain the function number. Combined with the original 3 bits
allocated for the function number, this allows for 256 functions.
This is enabled by default, but it's expected to be a no-op on currently
supported hardware. It's a prerequisite for supporting PCI SR-IOV, and
I want the ARI support to go in early to help shake out any bugs in it.
ARI can be disabled by setting the tunable hw.pci.enable_ari=0.
Reviewed by: kib
MFC after: 2 months
Sponsored by: Sandvine Inc.
My PCI RID changes somehow got intermixed with my PCI ARI patch when I
committed it. I may have accidentally applied a patch to a non-clean
working tree. Revert everything while I figure out what went wrong.
Pointy hat to: rstone
I/O windows, the default is to preserve the firmware-assigned resources.
PCI bus numbers are only managed if NEW_PCIB is enabled and the architecture
defines a PCI_RES_BUS resource type.
- Add a helper API to create top-level PCI bus resource managers for each
PCI domain/segment. Host-PCI bridge drivers use this API to allocate
bus numbers from their associated domain.
- Change the PCI bus and CardBus drivers to allocate a bus resource for
their bus number from the parent PCI bridge device.
- Change the PCI-PCI and PCI-CardBus bridge drivers to allocate the
full range of bus numbers from secbus to subbus from their parent bridge.
The drivers also always program their primary bus register. The bridge
drivers also support growing their bus range by extending the bus resource
and updating subbus to match the larger range.
- Add support for managing PCI bus resources to the Host-PCI bridge drivers
used for amd64 and i386 (acpi_pcib, mptable_pcib, legacy_pcib, and qpi_pcib).
- Define a PCI_RES_BUS resource type for amd64 and i386.
Reviewed by: imp
MFC after: 1 month
are mostly useful for debugging.
- hw.pci.clear_bars ignores all firmware-assigned ranges for BARs when
set.
- hw.pci.clear_pcib ignores all firmware-assigned ranges for PCI-PCI
bridge I/O windows when set.
MFC after: 1 week
beasts still exist unfortunately. More details can be found in other
references, but the short version is that bridges with this bit set ignore
I/O port ranges that alias to valid ISA I/O port ranges. In the driver
this requires not allocating these alias regions from the parent device
(so they are free to be acquired by ISA devices), and ensuring no child
devices use resources from these alias regions.
- Change the pcib_window structure to allow for an array of backing
resources rather than a single resource and update the existing code
to cope with this. Some of the coping requires using the saved
base and limit values in pcib_window instead of using rman operations
on the backing resource.
- Add special handling for allocating and adjusting the I/O port window
of an ISA-enabled bridge to only allocate the non-alias ranges and
add those to the associated resource manager.
- Reject I/O port allocations for a fixed request that conflicts with an
ISA alias range.
- Remove the "no prefected decode" verbose printf during boot. The absence
of a "prefetched decode" line is sufficient.
- Replace the "subtractively decoded bridge" verbose printf with a single
printf that lists all the "special" decoding modes of a bridge: ISA,
subtractive, and VGA.
- Add a custom bus_release_resource() method to the PCI bus driver so that
it can properly free resources for I/O windows of PCI-PCI bridges.
(These resources are not stored in the bridge device's resource list.)
PR: misc/179033
MFC after: 2 weeks
VMware up to at least ESXi 5.1. Actually, using INTx in that case instead
may still result in interrupt storms, with MSI being the only working
option in some configurations. So introduce a PCI_QUIRK_DISABLE_MSIX quirk
which only blacklists MSI-X but not also MSI and use it for the VMware
PCI-PCI-bridges. Note that, currently, we still assume that if MSI doesn't
work, MSI-X won't work either - but that's part of the internal logic and
not guaranteed as part of the API contract. While at it, add and employ
a pci_has_quirk() helper.
Reported and tested by: Paul Bucher
- Use NULL instead of 0 for pointers.
Submitted by: jhb (mostly)
Approved by: jhb
MFC after: 3 days
on the secondary side of a bridge will not be propagated to the primary
bus unless this is enabled. Busmastering is not enabled by default (we
have relied on firmware to set this bit to date). The OS needs to set it
for any bridges not configured by system firmware.
Tested by: Steve Polyack korvus comcast net
MFC after: 2 weeks
the request up the tree in order to be on the safe side. Growing windows
in this case would mean to switch resources to positive decoding and
it's unclear how to correctly handle this. At least with ALi/ULi M5249
PCI-PCI bridges, this also just doesn't work out of the box.
Reviewed by: jhb
MFC after: 3 days
growing "downward" (moving the start address down). First, an off by
one error caused the end address to be moved down an extra alignment
chunk unnecessarily. Second, when aligning the new candidate starting
address, the wrong bits were masked off.
Tested by: Andrey Zonov andrey zonov org
MFC after: 3 days
one. Interestingly, these are actually the default for quite some time
(bus_generic_driver_added(9) since r52045 and bus_generic_print_child(9)
since r52045) but even recently added device drivers do this unnecessarily.
Discussed with: jhb, marcel
- While at it, use DEVMETHOD_END.
Discussed with: jhb
- Also while at it, use __FBSDID.
resource allocation on x86 platforms:
- Add a new helper API that Host-PCI bridge drivers can use to restrict
resource allocation requests to a set of address ranges for different
resource types.
- For the ACPI Host-PCI bridge driver, use Producer address range resources
in _CRS to enumerate valid address ranges for a given Host-PCI bridge.
This can be disabled by including "hostres" in the debug.acpi.disabled
tunable.
- For the MPTable Host-PCI bridge driver, use entries in the extended
MPTable to determine the valid address ranges for a given Host-PCI
bridge. This required adding code to parse extended table entries.
Similar to the new PCI-PCI bridge driver, these changes are only enabled
if the NEW_PCIB kernel option is enabled (which is enabled by default on
amd64 and i386).
Approved by: re (kib)